Design of shoring and bracing for 17 foot tall reinforced concrete foundation walls to permit the walls to be back-filled prior to the installation of the steel framing and concrete slab at the first floor level. The shoring design utilized standard, off-the-shelf bracing products and post-installed concrete anchors commonly used in tilt-up concrete construction to expedite erection of the shoring and bracing.